Responsive. Ready. Rock star treatment.


For live, friendly, technical support please call us at 864-843-4343 or email support@sealevel.com
Categories
There are no subcategories in this category.
1 01. How do I access a Sealevel synchronous serial adapter from my software application?

Sealevel provides a synchronous serial driver, SeaMAC V4, to interface our synchronous serial adapters to your computer. No additional DLL or library files are necessary for basic operation. For advanced configuration, status and control features, use the…

2 02. Does Sealevel provide source code samples for use with SeaMAC V4?

SeaMAC V4 automatically installs application samples with source code in the 'Samples' subdirectory. In Microsoft Windows 7, Vista, XP and 2000 operating systems, samples are located on your hard drive under C:\Program Files\SeaMAC V4\Samples\.

3 03. What is the maximum data rate of Sealevel synchronous serial cards?

Sealevel synchronous serial products fall into three categories: ZiLOG Z16C32 based devices, ZiLOG Z85230 based devices and older ISA DMA channel cards. The fastest family of Sealevel synchronous serial products is built around the ZiLOG Z16C32 IUSC which…

4 04. Where can I get the user manual for the ZiLOG synchronous serial controller chip (Z85230 or Z16C32)?

The Z85230 PDF user manual and the Z16C32 PDF user manual are both available on the ZiLOG web site and are used on a variety of Sealevel synchronous serial products.

5 05. How can I verify that my synchronous serial card is working?

Sealevel provides WinSSD, a helpful software utility that allows easy verification your synchronous card is working properly. After you install the SeaMAC V4 synchronous software driver onto your system, WinSSD will be located in the SeaMAC folder in the…

6 06. What clock pins do I need to connect when testing my synchronous serial card with a loop back?

For Sealevel synchronous serial products, after connecting the Transmit (TX) and Receive (RX) pins, you will need to connect the Clock Output pin (TSET) to the Clock Input pin (RXC). In most cases, the Clock Output pin (TSET) should be used as the board's…

7 07. What is the difference between ‘Set Configuration’ or ‘Save Configuration’ in WinSSD?

The 'Set Configuration' and 'Save Configuration' buttons are only available in the synchronous version of WinSSD test utility that is included in the SeaMAC software suite. Clicking the 'Set Configuration' button will send the configuration currently defined…

8 08. Why does my Sealevel synchronous adapter not show up as a COM port?

Sealevel synchronous serial adapters enumerate as SeaMAC devices in Windows. Since the devices are zero-indexed, the first installed port will be ‘SeaMAC0’. SeaMAC devices support additional features that are not typically found on asynchronous serial…

9 09. How will my Sealevel synchronous serial adapter appear in Windows Device Manager?

In Windows Device Manager, Sealevel synchronous serial adapters will install under the ‘SeaMAC Device’ category. The device names for Sealevel synchronous serial adapters, with part numbers in parenthesis, are shown as they appear in Device Manager. PCI…

10 10. Is synchronous mode the only mode that can use a BERT pattern?

Section 2.5 of the ITU O.151 document basically states that a pattern can be encapsulated by the framing bits of a protocol, if necessary. Therefore, the BERT pattern can be used in a synchronous mode, such as SDLC/HDLC, as well as asynchronous mode.